Back to Panic / Exit  Home page
Introduction 2200 & F2200 2260 & F2260 LBR 2260 & F2260

2260 & F2260 Series
Vertical Rod Type Exit Device

Specifications

  • For Doors
    • 1-3/4" thick standard optional 2-1/4" thick.  3-3/4" minimum stile width required for single door application.  3-1/2" minimum stile width required for double door application.  Lever trims available.
  • Chassis
    • Nonferrous alloy (Panic Grade), steel (Fire Grade)
  • Cover
    • Nonferrous alloy.  Covers stock hollow metal doors with 161 cutout.
  • Mounting
    • Furnished standard with wood and machine screws.  Thru bolts are standard packaging on fire rated devices.
  • Alarm
    • Available.  Prefix "Alrm" before part #.
  • End Cap
    • Steel construction.
  • Hand
    • Easily field reversible.  Specify at time of order LHRB, RHRB for convenience.
  • Latch Bolt, Spring
    • Stainless steel.
  • ANSI Standard
    • A156.3, Grade 1.
  • Rail Assembly
    • Heavy gauge steel, painted.
  • Strike
  • Dogging Feature
    • Allen-type key furnished standard on non-fire labeled devices.
  • UL and ULC Listed
    • 2260 Series for panic.  F2260 Series for fire exit hardware for all types of 8' x 8' double doors for up to 3 hour fire labeled installations, conforms to standards UL10C and UBC 7-2-1997 codes.
  • Finish
    • Aluminum (alum), dark bronze duranodic (duro), gold..
  • Door Size
    • 2260V3694 and F2260V3684 for 36" x 84" doors.
    • 2280V4896 and F2280V4896 for 48" x 96" doors.
    • 2290V3696 and F2290V3696 for 36" x 96" doors.
    • 2250V36120 for 36" x 120" doors.
    • 2240V48120 for 48" x 120" doors.

Dimensions
Touch bar height to finished floor 41" (1043mm) at center
Touchbar Projection
         
Neutral
          Depressed

2-1/2" (64mm)
1-3/4" (45mm)
Center case 5-1/8" x 2-3/4" x 2" (129mm x 69mm x 52mm)
Device length
         
Short 3' (914mm)
          Long 4' (1219mm)

2'9" to 3' (840mm to 914mm) door size
2'9" to 4' (1145mm to 1219mm) door size
Panic Grade top & bottom latch case 3-15/16" x 2-1/8" x 1-3/8" (100mm x 52mm x 42mm)
Fire grade top latch case 3-15/16" x 2-11/16" x 2-1/16" (100mm x 68mm x 53mm)
Fire grade bottom latch case 3-15/16" x 2-1/8" x 1-3/8" (100mm x 52mm x 42mm)
Top and bottom rod length for 36" x 84" doors Top rod 43-1/4" (1100mm), bottom rod 37-3/4" (960mm)
Top and bottom rod length for 48" x 96" doors Top rod 53-1/16" (1350mm), bottom rod 37-3/4" (960mm)
Vertical rods 1/2" (13mm) Round tubing

Minimum Stile Requirements
DOUBLE DOOR - With Two Vertical Rod Type Exit Devices

3-1/2" Min. Stile