| FIRE EXTINGUISHER CABINETS |
|
|
|||||
|
|
|
||||
| Model Number |
Trim
Style and Projection |
Inside
Box Dimensions H x W x D |
Outside
Trim Dimensions H x W** |
Rough Opening H x W x D |
Recommended Extinguisher Capacity |
|
| C2409-R | Rec. 5/16 | 24 x 9½ x 3½ | 27½ x 13 | 25 x 10½ x 4 | MP2½,MP5, MP5-A,DC2½ DC5,MP6,MP10, DC6,DC10 |
|
| FS | C2409-R | Rec. 5/16 | 24 x 9½ x 3½ | 27½ x 13 | 261/8 x 115/8 x 45/8 | |
| C2409-5R | Semi-Rec. 1½ | 24 x 9½ x 3½ | 27½ x 13 | 25 x 10½ x 2¾ | ||
| FS | C2409-5R | Semi-Rec. 1½ | 24 x 9½ x 3½ | 27½ x 13 | 261/8 x 115/8 x 37/8 | |
| C2409-6R | Semi-Rec. 2½ | 24 x 9½ x 3½ | 27½ x 13 | 25 x 10½ x 1½ | ||
| FS | C2409-6R | Semi-Rec. 2½ | 24 x 9½ x 3½ | 27½ x 13 | 261/8 x 115/8 x 25/8 | |
| C2409-RT | Trimless | 24 x 9½ x 3½ | -- | - x - x 4* | ||
| C2409-SM | Surface Mtd. | 27½ x 13 x 3½ | 27½ x 13 | -- | ||
| C 3216-R | Rec. 5/16 | 32 x 16 x 3½ | 35½ x 19½ | 33 x 17 x 4 | All of above, PW2½,MP20, DC20,CD5, CD10, WC-6L |
|
| FS | C 3216-R | Rec. 5/16 | 32 x 16 x 3½ | 35½ x 19½ | 341/8 x 181/8 x 45/8 | |
| C 3216-RL | Semi Rec. 2½ | 32 x 16 x 3½ | 35½ x 19½ | 33 x 17 x 1½ | ||
| FS | C 3216-RL | Semi-Rec. 2½ | 32 x 16 x 3½ | 35½ x 19½ | 341/8 x 181/8 x 25/8 | |
| C 3216-RT | Trimless | 32 x 16 x 3½ | -- | - x - x 4* | ||
| C 3216-SM | Surface Mtd. | 35½ x 19½ x 3½ | 35½ x 19½ | -- | ||
| C 3228-R | Rec. 5/16 | 32 x 28 x 3½ | 35½ x 31½ | 33 x 29 x 4 | Two ea. of the listed: PW2½,MP10, DC10,CD5,CD10, WC-6L |
|
| FS | C 3228-R | Rec. 5/16 | 32 x 28 x 3½ | 35½ x 31½ | 341/8 x 301/8 x 45/8 | |
| C 3228-RT | Trimless | 32 x 28 x 3½ | -- | - x - x 4* | ||
| C 3228-SM | Surface Mtd. | 35½ x 31½ x 3½ | 35½ x 31½ | -- |
|
NOTE: All recessed (R-5/16") and trimless (RT) Cameo cabinets listed above comply with ADA wall projection guidelines. Semi-recessed and surface-mounted Cameo cabinets' compliance with ADA wall projection guidelines depends on several location and installation issues. |
|
NOTE: "FS" models denote Larsen's "Flame-Shield" fire-rated cabinets. When specifying Larsen's "Flame-Shield" fire-rated cabinet option for the Cameo Series, refer to the dimension chart on this page and select from the models with an "FS" prefix. For complete details of the "Flame-Shield" option. |
| * Trimless cabinets must be
installed before drywall because their plaster stops must be behind the
drywall. Trimless are not recommended for block wall installation. ** Deduct ¾ from H x W dimensions for cabinets with aluminum trim. This does not apply to the "FS" fire-rated option. |
|
Bubble Design:
|
Bubble & Lettering Colors:
|